APG 80
Product: GM NG
Alternator: ECP 32-3L/4 B
Control System: 4520
INTRODUCTION
Certificate
General Characteristics
3 Phase, 50 Hz, PF 0.8
ENGINE SPECIFICATIONS
ALTERNATOR SPECIFICATIONS
SIZE and WEIGHT
STANDARD SPECIFICATIONS
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
TS ISO 8528
CE
SZUTEST
2000/14/EC
Model Name |
APG 80 |
||
---|---|---|---|
Frequency (Hz) |
50 |
||
Fuel Type |
Natural Gas |
||
Engine Made and Model |
GM NG - PSI 8.8L |
||
Alternator Made and Model |
Mecc Alte - ECP 32-3L/4 B |
||
Control Panel Model |
4520 |
||
Canopy | AK40-APG80 |
Voltage | STANDBY RATING (ESP) | PRIME RATING (PRP) | Standby Amper | ||
---|---|---|---|---|---|
kVA | kW | kVA | kW | ||
400/231 | 80 | 64 | - | 115.47 |
STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.
PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
Engine |
GM NG |
||
---|---|---|---|
Engine Model | PSI 8.8L | ||
NO. OF CYLINDERS AND BUILD | 8 cylinders - V type | ||
BORE AND STROKE | mm | 110.49 X 114.30 | |
TOTAL DISPLACEMENT | L | 8.800 | |
Aspiration | Naturally Aspirated | ||
COMPRESSION RATIO | 10.0:1 | ||
RATED SPEED (RPM) | d/dk | 1500 | |
OIL CAPACITY | L | 8,5 | |
Fuel Type | |||
Natural Gas | |||
Governor System | |||
Electronic | |||
Operating Voltage (Vdc) | |||
12 Vdc | |||
Battery and Capacity (Qty/Ah) | 1x85 | ||
Cooling Method | |||
Water Cooled | |||
Cooling Fan Air Flow (m3/min) | 120 | ||
Coolant Capacity (engine only / with radiator) (lt) | /25,5 | ||
Air Filter | |||
Dry Type |
Manufacturer | Mecc Alte | |
---|---|---|
Alternator Made and Model | ECP 32-3L/4 B | |
Frequency (Hz) | Hz | 50 |
Power (kVA) | kVA | 75 |
Design | Brushless | |
Voltage | V | 400 |
Phase | 3 | |
A.V.R. | DSR | |
Voltage Regulation | (+/-) | 1 |
Insulation System | H | |
Protection | IP23 | |
Rated Power Factor | 0.8 | |
WEIGHT COMP. GENERATOR (Kg) | 293 | |
COOLING AIR (m³/min) | m3 | 11.8 |
Open Type | DRY WEIGHT (kg.) (kg.) |
LENGTH (mm.) |
WIDTH (mm.) |
HEIGHT (mm.) |
TANK CAPACITY (lt.) (Lt.) |
---|---|---|---|---|---|
1120 | 2150 | 1050 | 1543 | ||
CANOPY | DRY WEIGHT (kg.) (kg.) |
LENGTH (mm.) |
WIDTH (mm.) |
HEIGHT (mm.) |
TANK CAPACITY (lt.) (Lt.) |
AK40-APG80 |
1300 | 3100 | 1050 | 1641 | N/A |
Heavy duty, water cooled naturalgas engine
46/50 °C ambient rated radiator with mechanical fan
Protective grille for fan and rotating parts
Electric starter and charge alternator
Starting battery (with lead acid) including rack and cables
Engine jacket cooling heater
Base frame design incorporates an integral fuel tank and anti-vibration isolators
Flexible fuel connection hoses
Single bearing, class H alternator
Industrial exhaust silencer and steel belows supplied separately
Static battery charger
Manual for use and installation
OPTIONAL EQUIPMENTS
46/50 °C ambient rated radiator with mechanical fan
Protective grille for fan and rotating parts
Electric starter and charge alternator
Starting battery (with lead acid) including rack and cables
Engine jacket cooling heater
Base frame design incorporates an integral fuel tank and anti-vibration isolators
Flexible fuel connection hoses
Single bearing, class H alternator
Industrial exhaust silencer and steel belows supplied separately
Static battery charger
Manual for use and installation
ENGINE
- Remote Radiator Cooling
- Low Coolant level alarm
- Anti-Condensation heater
- Over sized alternator
- Main line circuit breaker
- Remote annunciator panel
- Uzağa alarm paneli
- Alarm output relays
- Earth fault, single set
- Charging ammeter
- Üç kutuplu kontaktör
- Four Pole Contactor
- Manual oil drain pump
- Electrical oil drain pump
- Enclosure: weater protective or sound attenuated
- Duct adapter ( on radiator)
- Inlet and outlet motorised louvers
- Tool kit for maintenance
- Supplied with oil and coolant - 30 °C
- Automatic transfer switch
Control System: 4520
1 - Main Status and instrumentation display
2 - Menu navigation buttons
3 - Auto mode
4 - Manual mode / start button
5 - Reset/Stop button
2 - Menu navigation buttons
3 - Auto mode
4 - Manual mode / start button
5 - Reset/Stop button
Devices
Comonents installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface.Polyester composite powder topcoat forms high gloss and extremely durable finish. Lockable hinged panel door provides for easy component access.
INSTALLATION
DSE, model 4520 auto mains failure control module.
Static battery charger.
Emergency stop push button and fuses for control circuits.
CONSTRUCTION and FINISH
Static battery charger.
Emergency stop push button and fuses for control circuits.
Comonents installed in sheet steel enclosure. Phosphate chemical, pre-coating of steel provides corrosion resistant surface.Polyester composite powder topcoat forms high gloss and extremely durable finish. Lockable hinged panel door provides for easy component access.
Control panel is mounted generating set baseframe on robust steel stand or power module.
Located at side of generating set with properly panel visibility.
GENERATING SET CONTROL UNIT
Located at side of generating set with properly panel visibility.
The DSE 4520 conrol module is a standard addition to our generator sets between 10kva and 20kva and it has been designed to start and stop diesel generating sets that include electronic and non electronic engines. The DSE 4520 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable for controlling a standby generating set in conjunction with an automatic transfer switch. The DSE4520 also indicates operational status and fault conditions, automatically shutting down the generating set and indicating faults by means of its LCD display on the front panel.
STANDARD SPECIFICATIONS
- *Microprocessor controlled.
- *LCD display makes information easy to read.
- *Front panel programming and also via PC software.
- *Soft touch membrane keypad and two key menu navigation.
- *Event logging (15) showing date and time.
- *Date and time engine exercise mode and maintenance scheduler.
- *Control buttons; stop, manuel/start, auto, menu navigation.
STATIC BATTERY CHARGER
STANDARD SPECIFICATIONS
- *Microprocessor controlled.
- *LCD display makes information easy to read.
- *Front panel programming and also via PC software.
- *Soft touch membrane keypad and two key menu navigation.
- *Event logging (15) showing date and time.
- *Date and time engine exercise mode and maintenance scheduler.
- *Control buttons; stop, manuel/start, auto, menu navigation.
Instruments
ENGINE
Engine speed
Oil pressure
Coolant temperature
Run time
Battery volts
Engine maintenance due
GENERATOR
Voltage (L-L, L-N)
Current (L1-L2-L3)
Frequency
kVA
kW
Pf
kVAr
kWh, kVAh, kVArh
MAINS
Voltage (L-L, L-N)
Frequency
ENGINE
Engine speed
Oil pressure
Coolant temperature
Run time
Battery volts
Engine maintenance due
GENERATOR
Voltage (L-L, L-N)
Current (L1-L2-L3)
Frequency
kVA
kW
Pf
kVAr
kWh, kVAh, kVArh
MAINS
Voltage (L-L, L-N)
Frequency
Protection Circuits
WARNING
Charge failure
Battery Low/High voltage
Fail to stop
Low fuel level (opt.)
Over current
PRE-ALARMS
Low oil pressure
High engine temperature
Over /Under speed
Under/over generator frequency
Under/over generator voltage
ECU warning
SHUT DOWNS
Fail to start
Emergency stop
Low oil pressure
High engine temperature
Low coolant level (opt.)
Over /Under speed
Under/over generator frequency
Under/over generator voltage
Oil pressure sensor open
ELECTRICAL TRIP
Generator over current
WARNING
Charge failure
Battery Low/High voltage
Fail to stop
Low fuel level (opt.)
Over current
PRE-ALARMS
Low oil pressure
High engine temperature
Over /Under speed
Under/over generator frequency
Under/over generator voltage
ECU warning
SHUT DOWNS
Fail to start
Emergency stop
Low oil pressure
High engine temperature
Low coolant level (opt.)
Over /Under speed
Under/over generator frequency
Under/over generator voltage
Oil pressure sensor open
ELECTRICAL TRIP
Generator over current
Options
High oil temperature shut down
Low fuel level shut down
Low fuel level alarm
High fuel level alarm
High oil temperature shut down
Low fuel level shut down
Low fuel level alarm
High fuel level alarm
Standards
Elecrical Safety / EMC compatibility
BS EN 60950 Electrical business equipment
BS EN 61000-6-2 EMC immunity standard
BS EN 61000-6-4 EMC emission standard
Elecrical Safety / EMC compatibility
BS EN 60950 Electrical business equipment
BS EN 61000-6-2 EMC immunity standard
BS EN 61000-6-4 EMC emission standard
● Battery charger is manufactured with switching-mode and SMD technology and ıt has high efficinecy. Battery charger models' output V-I characteristic is very close to square and output is 5 amper, 13,8 V for 12 volt and 27,6 V for 24 V . Input 198 - 264 volt AC. Proline 2405 has fully output shot circuit protection and ıt can be used as a current source. Proline 1205/2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear alternatives. The charger is fitted with a protection diode across the output. Connect charge fail relay coil between positive output and CF output. They are equipped with RFI filter to reduce electrical noise radiated from the device. Galvanically isolated input and output typically 4kV for high reliability.
Canopy: AK40-APG80
STANDARD SPECIFICATIONS
CANOPY MODEL | AK40-APG80 | |
---|---|---|
WIDTH | mm. | 1050 |
LENGTH | mm. | 3100 |
HEIGHT | mm. | 1641 |
TANK CAPACITY (lt.) | Lt. | N/A |